Short answer
Check the refrigerant on every spec sheet before you import. In the EU, Regulation (EU) 2024/573 prohibits placing self-contained refrigeration equipment with fluorinated gases of GWP 150 or more on the market (with limited, time-bound exemptions), which favours R290. In the US, EPA Technology Transitions rules set GWP limits by product type. R22 is an ozone-depleting HCFC being phased out worldwide.
Global warming potential at a glance #
GWP compares the warming effect of a gas with CO₂ over 100 years. Commonly cited values (IPCC AR4, as used in EU F-gas reporting) are:
| Refrigerant | Type | GWP (100-yr) | Used in our range |
|---|---|---|---|
| R290 (propane) | Hydrocarbon (natural) | 3 | M77-C8, MC12F, TS4CD, JUC-60, HB4, CC-DT series |
| R134a | HFC | 1,430 | Nitro DT, soda fountains, sparkling water, ICTM cocktail, beer |
| R404A | HFC blend | 3,922 | ECOT-H2, JZICT-2, CL ice machines |
| R22 | HCFC (ozone-depleting) | 1,810 | LZ-60 ice maker |
European Union #
Regulation (EU) 2024/573 bans placing on the market self-contained refrigeration equipment (except chillers) that contains fluorinated gases with a GWP of 150 or more from 1 January 2025, except where needed to meet site safety requirements.
Commission Implementing Regulation (EU) 2025/33 granted a time-limited exemption for certain self-contained foodservice equipment types, including some dispensers, until 30 June 2026. Importers should check the current status and the exact equipment category with their compliance adviser.
United States #
The EPA’s Technology Transitions rules under the AIM Act restrict high-GWP HFCs by sector and product type, and the rule was revised in 2026. Check EPA’s current sector tables for your equipment category and the manufacture/import compliance date before shipping.
Working with R290 #
R290 is flammable (safety class A3), so charge sizes are limited and installation must follow the manufacturer’s ventilation guidance. Several of our R290 units list “ventilation” as an installation requirement. Service technicians need hydrocarbon training and tools.
Importer checklist #
- Confirm refrigerant type and charge on the nameplate and spec sheet.
- Check national rules for that refrigerant and equipment category.
- Ask whether an R290 or other low-GWP version is available.
- Make sure local technicians can service the refrigerant.
Sources
Product figures in this article are taken from our model specifications. Regulatory information is general guidance, not legal advice — confirm requirements with your local authority or compliance adviser.